Longstreet Theatre

Located at the corner of Sumter and Greene Streets, the Longstreet Theatre is
a 312 seat arena stage.
The stage deck includes a hydraulic elevator that allows scene shifting from
the basement during performances.
The wire mesh suspension grid is 21'-0" above the stage deck. Technicians walk
on the wire mesh to mount the lighting equipment. The system uses a Colortran
Computer Light Board, Kliegl Dimming System, and Yamaha and Shure Sound System.
I. House Information
Type of Theatre- Arena
Lobbies are located on the 1st, 2nd, and 3rd floors
House size 70'-6" x 64'-6"
Number of seats: 312
Box Office located on the 1st floor
Theatre entrance on the 3rd floor
Refreshment counter on the 2nd floor
Theatre accessed by stairs or by elevator

Select here for Seating
Chart for Longstreet Theatre.
II. Dressing Rooms
There are four dressing rooms, 2 located under the stage level (2nd floor) and 2 located
on the first floor. Access is by stairwell. All dressing rooms have mirrors, make-up
lights showers, sinks, lavatory, and costume racks.
Upper men's dressing room capacity: 8
Lower men's dressing room capacity: 10
Upper women's dressing room capacity: 10
Lower women's dressing room capacity: 10
III. Stage dimensions
A. Stage Dimensions
- Width: booth side to gallery side 32'-0"
other side 32'-6"
from vom 1 to vom 3 30'-8"
from vom 2 to vom 4 30'-7"
lift is 19'-9" x 19'-9"
- Grid Height:
20'-9" from grid to stage floor
12'-0" from grid to top row of seats
B. Floor
- Surface is masonite painted with flat black latex.
- There is one trap in the stage floor located
Trap location:
C. Lift Information
D. General Stage Information
- Crossover is around stage
E. Crew
The house is crewed by both staff and students
IV.Lighting
A. Control board
Colortran Prestige 2000 board with 300 cues per show capacity, 200 control channels,
24 sub masters with bump buttons on 12 . There is proportional soft patch of up
to 400 dimmers. The display is a Taxon 650 color monitor with an extra monitor
for use in the house during technicals. Output is RS 422. Playback on 4 faders. The
location of the board is in the light booth at the back of the house. The booth
can be accessed 3rd floor lobby.
B. Dimmers
125 working kliegl analog dimmers. The dimmer vault is located above the tension
grid and is accessed by a permenate ladder.
C. Circuits
See circuit diagram
D. Lighting Positions
Lighting positions are flexible by moving the pipe configuration. There is house
configuration see house light plot
E. Lighting Inventory
18-Altman Shakespeare 30' (600w)
16-Strand 6x12 (750-EHG)
2-Strand 6x16 (750- EHG)
16-Altman 6x12 (750-EHG)
2-Altman 6x16 (750-EHG)
23-Kliegl 6x14 (1K-Q1000 T6/CL)
7-Kliegl narrow (750-EHG)
23-Kliegl wide (750-EHG)BR>
29-Kliegl 6 Fresnel (750w-BTN)
21-Kliegl 8 Fresnel (1K-BVT)
8-Berkey Zoom 8 (1K-FEL)
9-10" Scoops (500w)
8-Beam Projectors (750)
8-Altman 30 degree (1K-FEL)
?-Century Fresnel
V. Sound
A. Sound console
Yamaha mixer model PM 1100 with 16 channels in 4 program outs
B. Amplification
- 3 Shure SR 105 amplifiers with 200 watt at 4 ohm or 70 volt output C. Output
- Sony TCWR 9 dual cassette deck
- Revox PR 99 MK 111 reel to reel
- 3 cart machines
D. Speakers
- House- 2 Yamaha S411SH 100watts at 8 ohm
- Booth Monitor- 2 JBL control monitors model 4301B
E. Misc.
- 2 Stereographic equalizers
- Patch panel from output device to board
- Patch panel from amplifier to speaker
F. Jack locations
- Speaker
vom 1 #1
vom 2 #2
vom 3 #3
vom 4 #4
grid D,12 #1
grid L,12 #2
grid m,3 #3
grid E,3 #4
- Microphone
vom 1 mic 1 & 2
vom 2 mic 2
vom 3 mic 3
vom 4 mic 3 & 4
basement by lift controls
light booth
grid
VI. Communications
A. Intercom
- Power supply
Clear com CS 200 2 channel base station located in sound control booth
- Head sets
2 single muff, 3 double muff and 2 phones
- Belt packs
5 working
- intercom wall jack locations
light booth sound booth
vom 1 vom 2
vom 3 vom 4
basement drafting classroom
B. Monitors
- mic location - grid
- Speaker with variable volume control location
light booth basement
vom 1 vom 2
vom 3 vom 4
1st and 2nd floor men's dressing rooms
1st and 2nd floor women's dressing rooms
1st, 2nd, and 3rd floor lobbies
|